Home Contact Us Request A Quote About Elcon Jobs At Elcon
Ceramic Metallization
INDUSTRIES SERVED
Aerospace
Semiconductor
Vacuum Electronics
Telecommunications
Medical Components
Department of Energy
Department of Defense

SERVICES

Electro and Electroless Plating

Elcon Inc. Plating Department

At Elcon, we recognize the importance of quality plating as it reflects on the overall performance of the component.

We offer the following plating methods and specifications:

  • "Soft” Gold per MIL-G-45204, Type III, Grade A or per ASTM B488, Type III, Code A
    Silver per QQ-S-365, Type II (semi-bright), Grade B or ASTM B700 Type 1, Semibright, Class N
  • Electrolytic Nickel per QQ-N-290, Class 2 or ASTM B689, Type 1 or MIL-P-27418 (low stress)
  • Electroless Nickel-Boron per ASTM B607
  • Electrolytic Copper per ASTM B734

Specification

Mil

Superceded or Replaced

SAE/AMS/etc

ASTM

Copper Plating

 MIL-C-14550B
   

Superceded 1998

AMS 2418

ASTM B 734-97

Electroless Nickel Boron (.5%)

 

Superceded 2003

AMS 2399

 ASTM B607-91

Electroless Nickel Mid Phosphorous

MIL-C-26074

Superceded 2003

AMS 2404
AMS-C-26074

ASTM B 733-04

Gold Industrial (24 Carat)

MIL-G-45204

Replaced MIL-DTL-45204

AMS 2422

ASTM B488 -01
Type IIIA

Nickel Plating

QQ-N-290

Superceded 2001

AMS 2403

ASTM B 689-97

Sulfamate Nickel

MIL-P-27418

 Inactivated 1998

AMS 2403

 

Silver Plating

QQ-S-365

Inactivated 2001

 

ASTM B 700-08

Test plan for Processing solutions

 

 

ARP4992

 

Microsurface Test Methods

MIL-STD-883F

 

 

 

Calibration of Equipment

MIL-STD-45662

Replaced 1995

ANSIZ540.3

 

Hybrid Microcircuits

MIL-STD-1772

Superceded 1995

MIL-PRF-38534

 

Inspection System requirements

MIL-I-45208

Cancelled

AS9100B